Protect people, property, and code-sensitive openings with UL-listed fire doors, counter shutters, smoke curtains, and elevator containment systems. Supplied and installed across Kelowna and the Okanagan.
Fire-rated doors and smoke containment systems are your building’s last line of defense, engineered to slow fire spread, limit smoke migration, and protect people and assets while evacuation happens safely.
Maximum fire protection rating available.
Raise/lower cycle rating on fire door curtains.
Distinct fire & smoke product types to choose from.
Every product meets rigorous UL certification standards.
Tell us what you need protected and we’ll help you choose the right setup.
We supply and install the full CornellCookson fire product line, from heavy-duty rolling fire doors to UL-listed smoke curtains designed for elevators, atriums, and counter openings.
The industry standard for compartmentalizing commercial and industrial spaces. These UL-listed rolling fire doors protect building occupants by creating a reliable barrier that limits the spread of fire and smoke. Available in fire ratings from 45 minutes to 4 hours.
Fire Ratings: 45 min, 90 min, 3 hr, 4 hr
Standard: Up to 13.5'W × 12'H
Oversized: Up to 60'W × 40'H or 1,200 sq ft
Cycle Rating: Up to 50,000 cycles
Steel: 22/20/18 gauge galvanized or 300-series stainless
Mount: Masonry, structural steel, or drywall
Everything you get with a standard rolling fire door, plus enhanced energy efficiency and sound reduction. The Firemiser’s mineral wool insulation makes it the right choice for exterior openings, temperature-sensitive spaces, or anywhere noise control matters alongside fire protection.
Fire Ratings: 45 min, 90 min, 3 hr, 4 hr
R-Value: 5.3 / U-Value: 0.189
Standard: Up to 13.5'W × 12'H
Oversized: Up to 60'W × 40'H
Cycles: Up to 50,000
Ideal For: Exterior & sound-sensitive spaces
Everything you get with a standard rolling fire door, plus enhanced energy efficiency and sound reduction. The Firemiser’s mineral wool insulation makes it the right choice for exterior openings, temperature-sensitive spaces, or anywhere noise control matters alongside fire protection.
Fire Ratings: 45 min, 90 min, 3 hr, 4 hr
R-Value: 5.3 / U-Value: 0.189
Standard: Up to 13.5'W × 12'H
Oversized: Up to 60'W × 40'H
Cycles: Up to 50,000
Ideal For: Exterior & sound-sensitive spaces
The most compact fire-rated counter protection on the market. Designed for service windows, cafeteria counters, pharmacy pass-throughs, and bank teller windows, the Counter Fire Door delivers up to 3-hour UL-rated protection with the industry’s smallest footprint. No compromise on safety or aesthetics.
Max Width: 16 feet
Max Height: 10 feet / Max Area: 120 sq ft
Rating: Up to 3-hour UL-labeled
Smoke: UL 1794 labeled SmokeShield®
Finish: RAL powder coat; 22ga galv. or 304 stainless
Operation: In-tube hand crank (smallest footprint)
Awarded 2023 Best Fire Safety System by American Security Today, this UL-listed elevator smoke curtain prevents smoke from migrating between floors through elevator shafts, one of the leading causes of smoke-related fatalities in multi-storey buildings. The patented GuideLock™ technology guarantees a 100% sealed perimeter every time.
Application: Elevator shaft smoke containment
Max Size: 12'W × 12'H
Headroom: 7.25" needed (fits in 10" space)
Backup: 10-hour battery for power outages
Seal: GuideLock™ — guaranteed 100%
Approved: CA OSHPD (OPM-0523-19)
Awarded 2023 Best Fire Safety System by American Security Today, this UL-listed elevator smoke curtain prevents smoke from migrating between floors through elevator shafts, one of the leading causes of smoke-related fatalities in multi-storey buildings. The patented GuideLock™ technology guarantees a 100% sealed perimeter every time.
Application: Elevator shaft smoke containment
Max Size: 12'W × 12'H
Headroom: 7.25" needed (fits in 10" space)
Backup: 10-hour battery for power outages
Seal: GuideLock™ — guaranteed 100%
Approved: CA OSHPD (OPM-0523-19)
A smarter motor designed specifically for counter fire shutters. Unlike traditional tube-mounted operators, the AlarmGard® Conceal mounts in the corner of the headplate, dramatically reducing the headroom and backroom required. Plug-and-play wiring, AlarmGard® Logic failsafe, and a built-in backup battery make installation fast and operation reliable.
Headroom Savings: Reduces by 11" (34%)
Backroom: Over 50% less vs traditional motors
Battery Backup: Holds door open 1 hour
Power: 120VAC / 60Hz / 1-Phase
Capacity: Up to 20 cycles/hour
Range: 2'7"W up to 120 sq ft openings
The first-of-its-kind fabric fire protective curtain to achieve both a UL10D 3-hour fire protection rating and a UL1784 smoke and air infiltration listing simultaneously. Ideal for atriums, corridors, and openings in fire and smoke barrier walls where a rigid door isn’t practical. It disappears into the surrounding structure when not deployed.
Fire Rating: 3-hour (UL10D)
Smoke Rating: UL1784 listed
Max Size: 20'H × 30'W
Conceals Into: Wood, masonry, sheetrock, fascia
Backup: Battery backup included
Best For: Atriums, corridors, open-plan spaces
The first-of-its-kind fabric fire protective curtain to achieve both a UL10D 3-hour fire protection rating and a UL1784 smoke and air infiltration listing simultaneously. Ideal for atriums, corridors, and openings in fire and smoke barrier walls where a rigid door isn’t practical. It disappears into the surrounding structure when not deployed.
Fire Rating: 3-hour (UL10D)
Smoke Rating: UL1784 listed
Max Size: 20'H × 30'W
Conceals Into: Wood, masonry, sheetrock, fascia
Backup: Battery backup included
Best For: Atriums, corridors, open-plan spaces
When fire protection needs to be discreet, the ERC20 delivers. This factory-assembled, push-up counter shutter integrates its frame, hood, and fascia directly into the surrounding wall, arriving on-site complete and ready for a clean, effortless installation. The refined stainless steel profile suits food service, healthcare, retail, and educational facilities equally well.
Fire Rating: UL-rated 1½ hours
Max Size: 11'6"W × 6'H (between jambs)
Wall Thickness: 4½" min - 12" max
Operation: Push-up (manual)
Standard: 300-series stainless #4 finish
Colors: SpectraShield™ - 180+ powder coat options
Use this table to find the right product for your project’s fire rating, size, and application requirements.
| Product | Max Fire Rating | Max Size | SmokeShield® | Battery Backup | Best For |
|---|---|---|---|---|---|
| Roll-Up Fire Door (ERD10/11) | 4 Hours | 60'W × 40'H | ✓ | ✓ (optional) | Industrial & commercial openings |
| Firemiser Insulated Fire Door (ERD20/21) | 4 Hours | 60'W × 40'H | ✓ (ERD21) | ✓ (optional) | Exterior & sound-sensitive spaces |
| Counter Fire Door (ERC10/11) | 3 Hours | 16'W × 10'H | ✓ (ERC11) | — | Service windows, counters, pharmacies |
| SmokeShield® Elevator Curtain (ERF10) | Smoke Only | 12'W × 12'H | ✓ (core function) | ✓ 10 hours | Elevator shafts — smoke containment |
| AlarmGard® Conceal Operator | N/A (Operator) | Up to 120 sq ft | — | ✓ 1 hour | Counter fire door motor upgrade |
| SmokeShield® Fabric Fire Door (ERF20) | 3 Hours | 30'W × 20'H | ✓ (core function) | ✓ included | Atriums, corridors, open-plan spaces |
| Integral Frame Counter Shutter (ERC20) | 1½ Hours | 11'6"W × 6'H | ✓ (optional) | — | Food service, healthcare, retail |
Everything you need to know about shutter battery backup systems.
A fire rating (e.g., 45 min, 90 min, 3 hr, 4 hr) measures how long a product can resist the spread of flames and heat under standardized UL test conditions. A smoke rating, typically listed under UL1784, measures the product’s ability to restrict the passage of smoke and air. Some products, like the SmokeShield® line, carry both ratings. For most commercial projects, you will need both, and choosing the right product depends on your specific building code requirements and occupancy type.
Yes. Most jurisdictions require annual inspections of fire-rated assemblies, including rolling fire doors and smoke curtains. This typically involves a drop test to verify the door closes properly on alarm activation. Some products, like the SmokeShield® Elevator Curtain (ERF10), include curtain-mounted pressure-sensitive switches that can be tested without requiring full manual activation every time. We can advise on maintenance requirements as part of your installation.
GuideLock™ is a patented sealing mechanism used in the SmokeShield® Elevator Curtain (ERF10) and SmokeShield® Fabric Fire Door (ERF20). When the curtain deploys, GuideLock™ positively engages the curtain edges within the guide channels, guaranteeing a 100% perimeter seal with no gaps. This is especially critical for smoke containment, where even small gaps can allow dangerous smoke migration.
AlarmGard® refers to CornellCookson’s integrated alarm-response system built into compatible operators. When a fire alarm signal is received, AlarmGard® Logic automatically triggers the door to close (or release, in the case of a fusible link), providing a failsafe drop. After the alarm clears, AlarmGard® Logic enables the door to auto-reset without requiring manual intervention, an important feature for buildings where staff may not be immediately available to reset doors after a false alarm or drill.
Yes. Most products in the lineup offer color customization. The Integral Frame Counter Shutter (ERC20) offers SpectraShield™ powder coating in 180+ colors. Counter fire doors (ERC10/11) are available in RAL powder coat options with color-matched fasteners. Rolling fire doors have GalvaNex™ finishes in Gray, Tan, White, Brown, and Black. The SmokeShield® Elevator Curtain (ERF10) and Fabric Fire Door (ERF20) also accept custom powder coat finishes on hardware components. Contact us to discuss your specific color requirements.
Fire rating requirements are typically set by the International Building Code (IBC), local building bylaws, your fire marshal, and, in some cases, your insurance underwriter. The type of occupancy, proximity to fire walls, and opening size all factor in. Our team can help you interpret your requirements, or we can work directly alongside your architect or building inspector to specify the correct product.
SmokeShield® is a proprietary seal system from CornellCookson that adds UL1784-listed smoke and draft control to a fire door assembly. It is available as an optional upgrade on the Roll-Up Fire Door (ERD11/ERD21), Counter Fire Door (ERC11), and Integral Frame Counter Shutter (ERC20). The SmokeShield® Elevator Curtain (ERF10) and Fabric Fire Door (ERF20) incorporate smoke containment as their primary function, so SmokeShield® technology is built in by design.
Most of these products are suitable for both new construction and retrofit applications. The SmokeShield® Fabric Fire Door (ERF20) is explicitly designed for both. The Integral Frame Counter Shutter (ERC20) is factory-assembled to set directly into existing wall openings, making retrofit installation straightforward. Rolling fire doors can be surface-mounted (face of wall) or recessed between jambs depending on the space available. We assess your site conditions and recommend the most practical installation approach.
The AlarmGard® Conceal operator reduces headroom requirements by 11 inches, a 34% reduction compared to traditional tube-mounted motors. This is achieved by mounting the motor in the corner of the headplate rather than inside the barrel. For retrofits or spaces with low ceiling heights above counters, this compact design often makes motorized counter fire doors feasible where traditional operators would not fit.
Yes. Several products are available in 300-series stainless steel, including the Roll-Up Fire Door (ERD10/11/20/21), Counter Fire Door (ERC10/11), and Integral Frame Counter Shutter (ERC20, standard in #4 finish 300-series stainless). Stainless is particularly suited to food service, healthcare, and pharmaceutical environments where hygiene, corrosion resistance, and aesthetics are priorities.
A fire rating (e.g., 45 min, 90 min, 3 hr, 4 hr) measures how long a product can resist the spread of flames and heat under standardized UL test conditions. A smoke rating, typically listed under UL1784, measures the product’s ability to restrict the passage of smoke and air. Some products, like the SmokeShield® line, carry both ratings. For most commercial projects, you will need both, and choosing the right product depends on your specific building code requirements and occupancy type.
Fire rating requirements are typically set by the International Building Code (IBC), local building bylaws, your fire marshal, and, in some cases, your insurance underwriter. The type of occupancy, proximity to fire walls, and opening size all factor in. Our team can help you interpret your requirements, or we can work directly alongside your architect or building inspector to specify the correct product.
Yes. Most jurisdictions require annual inspections of fire-rated assemblies, including rolling fire doors and smoke curtains. This typically involves a drop test to verify the door closes properly on alarm activation. Some products, like the SmokeShield® Elevator Curtain (ERF10), include curtain-mounted pressure-sensitive switches that can be tested without requiring full manual activation every time. We can advise on maintenance requirements as part of your installation.
SmokeShield® is a proprietary seal system from CornellCookson that adds UL1784-listed smoke and draft control to a fire door assembly. It is available as an optional upgrade on the Roll-Up Fire Door (ERD11/ERD21), Counter Fire Door (ERC11), and Integral Frame Counter Shutter (ERC20). The SmokeShield® Elevator Curtain (ERF10) and Fabric Fire Door (ERF20) incorporate smoke containment as their primary function, so SmokeShield® technology is built in by design.
GuideLock™ is a patented sealing mechanism used in the SmokeShield® Elevator Curtain (ERF10) and SmokeShield® Fabric Fire Door (ERF20). When the curtain deploys, GuideLock™ positively engages the curtain edges within the guide channels, guaranteeing a 100% perimeter seal with no gaps. This is especially critical for smoke containment, where even small gaps can allow dangerous smoke migration.
Most of these products are suitable for both new construction and retrofit applications. The SmokeShield® Fabric Fire Door (ERF20) is explicitly designed for both. The Integral Frame Counter Shutter (ERC20) is factory-assembled to set directly into existing wall openings, making retrofit installation straightforward. Rolling fire doors can be surface-mounted (face of wall) or recessed between jambs depending on the space available. We assess your site conditions and recommend the most practical installation approach.
AlarmGard® refers to CornellCookson’s integrated alarm-response system built into compatible operators. When a fire alarm signal is received, AlarmGard® Logic automatically triggers the door to close (or release, in the case of a fusible link), providing a failsafe drop. After the alarm clears, AlarmGard® Logic enables the door to auto-reset without requiring manual intervention, an important feature for buildings where staff may not be immediately available to reset doors after a false alarm or drill.
The AlarmGard® Conceal operator reduces headroom requirements by 11 inches, a 34% reduction compared to traditional tube-mounted motors. This is achieved by mounting the motor in the corner of the headplate rather than inside the barrel. For retrofits or spaces with low ceiling heights above counters, this compact design often makes motorized counter fire doors feasible where traditional operators would not fit.
Yes. Most products in the lineup offer color customization. The Integral Frame Counter Shutter (ERC20) offers SpectraShield™ powder coating in 180+ colors. Counter fire doors (ERC10/11) are available in RAL powder coat options with color-matched fasteners. Rolling fire doors have GalvaNex™ finishes in Gray, Tan, White, Brown, and Black. The SmokeShield® Elevator Curtain (ERF10) and Fabric Fire Door (ERF20) also accept custom powder coat finishes on hardware components. Contact us to discuss your specific color requirements.
Yes. Several products are available in 300-series stainless steel, including the Roll-Up Fire Door (ERD10/11/20/21), Counter Fire Door (ERC10/11), and Integral Frame Counter Shutter (ERC20, standard in #4 finish 300-series stainless). Stainless is particularly suited to food service, healthcare, and pharmaceutical environments where hygiene, corrosion resistance, and aesthetics are priorities.
Talk to our Kelowna-based team. We’ll help you choose the right fire-rated product, confirm code compliance, and handle installation from start to finish.